Solar panels – Chêne-Bougeries

At a glance

Typical budget
CHF 18'100 – CHF 32'900
Midpoint
CHF 24'800
Grants found
1
Nearby companies
4

Worked examples in Chêne-Bougeries

Small project

CHF 9'800 – CHF 18'500

Typical project

CHF 18'100 – CHF 32'900

Large project

CHF 31'400 – CHF 55'800

ProjectQuantityLowHigh
Small project5 kWcCHF 9'800CHF 18'500
Typical project10 kWcCHF 18'100CHF 32'900
Large project18 kWcCHF 31'400CHF 55'800

Computed with our estimator for Chêne-Bougeries (regional factor included), standard finish. Only the project size changes.

Cost split (typical project)

  • Labour : CHF 8'700 (35 %)
  • Materials : CHF 13'700 (55 %)
  • Other costs : CHF 2'500 (10 %)

What the price covers

Included

  • Supply and installation
  • VAT
  • Inverter and grid connection

Not included

  • Permits and architect fees
  • Unexpected structural issues
  • Possible subsidies
  • Battery, roof refurbishment and structural reinforcement

Tips before you start

  • The federal one-off remuneration (Pronovo) lowers the cost of small systems.
  • Profitability depends mainly on how much power you use on site.
  • A suitably integrated roof system often only needs notification.

Your project in 5 steps

  1. 1. Estimate

    Set a budget range with the estimator.

  2. 2. Grants

    Apply before work starts.

  3. 3. Quotes

    Compare at least 3 quotes.

  4. 4. Permit

    Check with the municipality whether a permit is needed.

  5. 5. Works

    Follow the site and do a written handover.

Grants and subsidies

Canton

Solar PV — Geneva support

Variable additional grants; federal one-off payment by capacity.

Geneva strongly supports solar PV, with grants in addition to the federal one-off payment.

www.pronovo.ch

Check amounts and conditions with the provider before signing: apply before work starts in most cases.

Chêne-Bougeries's housing stock in figures

The federal building register lists 1'860 residential buildings with 6'386 dwellings in Chêne-Bougeries. 52% were built before 1980, before serious insulation standards, and 74% are still heated with oil or gas.

Only 12.7% of residential buildings in Chêne-Bougeries report a solar thermal system in the register, so most roofs are still free. Photovoltaics are not recorded there; check the solar cadastre for your roof.

52 %built before 1980
74 %heated by oil or gas
5.6 %electric hot water
12.7 %with declared solar thermal

Age of residential buildings

  • Before 191918 %
  • 1919–194512 %
  • 1946–196010 %
  • 1961–19706 %
  • 1971–19806 %
  • 1981–199012 %
  • 1991–20009 %
  • 2001–20109 %
  • Since 201118 %

Main heating energy

  • Gas54 %
  • Heating oil20 %
  • Heat pump19 %
  • District heating5 %
  • Electricity1 %
  • Wood1 %

Heating and hot water: which energies?

EnergyHeatingHot water
Gas54 %48.8 %
Heating oil20 %17.9 %
District heating5 %4.4 %
Heat pump19 %3.5 %
Electricity1 %5.6 %
Wood1 %1 %
Solar thermal0 %11.7 %

Each line gives the share of buildings using that energy, separately for heating and for hot water. The two columns do not always reach 100%: some buildings combine two systems, or reported none.

Type of heating system

  • Boiler (unspecified)66.4 %
  • Heat pump18.8 %
  • Heat exchanger (district)4.8 %
  • Condensing boiler4.4 %
  • Standard boiler4.3 %
  • Central electric heating0.7 %

A standard non-condensing boiler is usually older and less efficient.

Houses or apartment buildings?

  • Single-family houses74.5 %
  • Two-dwelling houses6.8 %
  • Apartment buildings (3+)18.7 %

5.3 % of buildings mix housing with shops or offices.

The typical building

storeys (median)
2
median footprint
129 m²
median dwelling area
98 m²

Renovations, heritage and volumes

For renovation projects in Chêne-Bougeries, official building register data provides a baseline for your planning. With 1860 buildings in the registry, please note that information regarding the renovation year is unavailable, and the building volume for the 1386 houses is not measured according to SIA 416 standards. Regarding heritage status, out of 1860 buildings, only 74 are known to the registry, with no protected status recorded. Due to this partial data coverage, it is essential to contact the municipality early in your planning process to discuss project requirements, as official records may not reflect all local constraints for your home.

0
buildings flagged as protected
status known for 74 of 1'860 buildings; check with the municipality

Source : OFS — RegBL (export communal complet). Existing residential buildings; percentages of recorded values.

Companies in the area

Heta Construction SA

1224 Chêne-Bougeries · about 0 km

Heta Construction SA is a company specializing in metal construction, thermal insulation, cold rooms, and solar installations.

hetaconstruction.com

Cuivretout SA

1224 Chêne-Bougeries · about 0 km

Geneva-based company with 40 years of expertise in tinsmithing, roofing, waterproofing, roof maintenance, and solar installations.

cuivretout.ch

MKP INVEST Sàrl

1224 Chêne-Bougeries · about 0 km

Geneva-based company specializing in electrical installations, photovoltaic systems, heat pumps, and telecommunication solutions.

prodelec.ch

R. Cirilli Sàrl

1225 Chêne-Bourg · about 0.9 km

Geneva-based company specializing in electrical installations, telephony, and technical building infrastructure.

spm-metallurgie.ch

Suggestions from the commercial register by distance and activity. Not an endorsement or partnership.

Useful local data

Rules of the canton of Geneva

These rules apply across the whole canton, not only in this town.

Permits

  • Competent authority : Office de l'urbanisme
  • Solar panels : Soumise à autorisation de construire, mais avec une procédure simplifiée si certaines conditions sont remplies (conformité au droit des zones, intégration paysagère et patrimoniale satisfaisante, puissance totale inférieure à 100 kVA). Procédure simplifiée possible par le biais d'une déclaration préalable, si les installations sont sur des toits en pente conformes ou sur des toits plats non visibles, ou dans certains périmètres d'aménagement (zone 4B, 5, 5A, 5B, 6).
  • Heat pump : Les pompes à chaleur air-eau ou air-air nécessitent une autorisation de construire si leur puissance dépasse 10 kW. Si elles sont installées à l'intérieur, elles sont soumises à la LCI (Loi sur les constructions et les installations) et non à la LALPT (Loi sur l'aménagement du territoire et les constructions). Pour les pompes à chaleur de puissance inférieure ou égale à 10 kW, une déclaration préalable est nécessaire, accompagnée d'une attestation de conformité acoustique. Des exigences en matière de bruit sont mentionnées pour les installations extérieures, avec des valeurs limites d'immissions fixées par l'Ordonnance sur la protection contre le bruit (OPB) et des règles spécifiques du règlement d'application de la LCI (rLCI). Un bureau spécialisé en acoustique est souvent requis pour les projets complexes.
  • Procedure : l'autorisation de construire

Source : Guide Installations Solaires et Thermopompes - Canton de Genève

Other works in Chêne-Bougeries

Solar panels in nearby towns